RGT-12SVC - Power Factor Controller 12 level +TCR with RS485 ModBus RTU
Failed to load pickup availability
Online payment by card - after completing the order you will be redirected to the payment gateway, payment confirmation will be sent to your email
Payment upon delivery - payment according to the payment instructions to the driver of the transport company
Bank transfer - you will receive a proforma invoice by email the next business day at the latest, containing the account number you entered when making the payment.
By invoice - this payment option is for partners who have concluded a framework agreement with our company.
If you want to use the last 2 methods, please call our manager and he will give you instructions on how to receive an invoice with or without VAT.
The electrical appliances we supply meet high quality standards, have a 24-month warranty and comply with all EU requirements.
In the event of a complaint, there will be no charges for returning goods.
12 steps + TCR Power factor controller with 2.9" graphic LCD screen and RS-485 (TENSE)
The RGT-12SVC reactive power controller (TENSE) is a fully automatic device for the optimal switching of compensation phases.
The digital processing of the values measured by the controller ensures high accuracy in the evaluation of the effective voltage, current, and power factor.
The installation of the device is fully automatic - the controller determines the size of the individual connected compensation steps by itself. These parameters can also be entered directly manually.
The controller switches the compensation steps on and off so that the reactive power is controlled with a minimal number of switching operations. At the same time, the controller takes into account the even loading of the individual steps and preferably switches the steps that have been de-energized the longest and have minimal residual charge. During the control process, the compensation steps are continuously monitored in parallel - faults and changes in values are detected, temporarily removed steps are periodically tested, and if necessary, they are reintroduced into the control process.
Generator input and generator compensation
Starting, discharging, and settling times can be set
Remote communication via RS485 (RS485 ModBus RTU)
Single-phase, two-phase, and three-phase capacitors and shunt reactors can be connected
Harmonic voltage and current can be observed up to the 31st harmonics
Total energy (import/export) can be monitored
THD-V and THD-I values of each phase can be viewed
Create power analysis (20 samples 9999 min.) - for capacitor selection